Construction TRZT = open with covertape TRHT = rest hole potting TRWT = mounted on a metal angle TRVTP = potted in a round housing - print version TRVTF = potted in a round housing - free wire TRVTE = potted in a rectangular housing - print version TRVTU = potted in a rectangular housing - flat plugs
|
|
Temperature class T40/B, on request insulation class F (155°C)
|
|
Protective class IP00 (for mounting in an appliance)
|
|
Phases 1 or 3
|
|
Frequency 48 Hz up to 400 Hz, other frequencies than 50 Hz lead to another power at the same type size
|
|
Safety standards VDE/SEV open and potted: EN 61558
|
|
Safety standards UL/CSA on request UL/CSA materials or UL-approval
|
|
Test voltage EN 61558-1-2/4: 5000 V pri - sec
|
|
Resistance to short-circuiting conditionally short circuit protected with - PTC - temperature fuse - temperature switch - mini fuse in other case no resistance to short-circuiting
|
|
Core insulation and housing Material: Polyamid 6 gf class B = 130°C with UL approval UL 94 V2
|
|
Insulants Polyester (Mylar) class B = 130°C with UL approval UL 94 V0
|
|
Copper wire Polyimid mod. class H = 180°C with UL approval
|
|
Screen winding Screen with copper tape, this reduces the max. power at the same type size
|
|
Transformer core lamination conform to DIN 41302 M0H, 0,3 mm thick (1,0 W/kg losses at 1,7 T) or M111-35N, 0,35 mm thick (1,1 W/kg losses at 1,5 T)
|
|
Terminals Pins (TRVTP/TRVTU) Solder tags Free wires Flexible wires Terminal connectors (TRWT) Plug pins 2,8 - 4,8 - 6,3 mm Cable lugs
|
|
Mounting with central mounting, two rubber washers, a metal disk or with a screw in the potted centre
|
|
Voltage depends on the size, max. depends on the type size, vacuum potting: 5000 V
|
|
Tappings possible
|
|
Current max. 2000 A
|
|