Transformers for ship- and airplane board nets


Datasheet as PDF
Toroidal safety and isolating transformer to DIN EN 61558-2-4 and 2-6 with 5000 V 50 Hz test voltage pri - sec and a power of 15 VA up to 10000 VA at 400 Hz


Transformer for airplane board nets


Fields of application


Nets in ships and airplanes that are operated with 400 Hz (board nets).


Description


- low weight, weighs only half of a conventional transformer
- without magnetic hum, low stray field
- partly short-circuit-proof or not short-circuit-proof
- reinforced insulation between primary and secondary
- flat profile allows special design of appliances


Technical data


1AC-isolating- and safety-transformer
voltage range primary 230 V or according to customers demand
frequency: 400 Hz
test voltage primary - secondary: 5000 V 50 Hz
temperature class: B
max. ambient temperature: 40°C
fire class: UL94V0
transformer class: IP00
terminals: pri and sec free wires
prepared for mounting with added mounting supply


Table


Secondary
power

Dimensions
in mm

Height without
mounting material

Efficiency

No-load current

Voltage factor

Copper weight

Total weight

30 VA

Ø 36

H 25

84 %

6 mA

1,16

0,04 kg

0,08 kg

40 VA

Ø 40

H 30

88 %

8 mA

1,14

0,045 kg

0,10 kg

50 VA

Ø 45

H 25

88 %

8 mA

1,14

0,05 kg

0,17 kg

80 VA

Ø 50

H 30

90 %

10 mA

1,11

0,06 kg

0,20 kg

100 VA

Ø 56

H 26

91 %

10 mA

1,11

0,08 kg

0,28 kg

120 VA

Ø 56

H 26

92 %

11 mA

1,10

0,10 kg

0,30 kg

150 VA

Ø 60

H 30

93 %

12 mA

1,09

0,13 kg

0,35 kg

200 VA

Ø 70

H 30

94 %

15 mA

1,08

0,15 kg

0,40 kg

225 VA

Ø 75

H 30

94 %

16 mA

1,07

0,17 kg

0,50 kg

250 VA

Ø 76

H 30

94 %

17 mA

1,07

0,20 kg

0,54 kg

300 VA

Ø 80

H 35

94 %

18 mA

1,06

0,25 kg

0,07 kg

400 VA

Ø 93

H 35

95 %

20 mA

1,06

0,30 kg

0,90 kg

500 VA

Ø 95

H 40

96 %

25 mA

1,05

0,40 kg

1,00 kg

600 VA

Ø 98

H 50

96 %

28 mA

1,05

0,55 kg

1,30 kg

700 VA

Ø 98

H 55

96 %

30 mA

1,05

0,60 kg

1,60 kg

800 VA

Ø 110

H 50

97 %

32 mA

1,04

0,65 kg

2,00 kg

900 VA

Ø 115

H 50

97 %

40 mA

1,04

0,70 kg

2,10 kg

1000 VA

Ø 120

H 60

97 %

50 mA

1,04

0,95 kg

2,50 kg

1200 VA

Ø 120

H 65

97 %

60 mA

1,03

1,00 kg

2,80 kg

1500 VA

Ø 130

H 70

97 %

70 mA

1,03

1,30 kg

3,70 kg

2000 VA

Ø 140

H 80

97 %

80 mA

1,03

1,60 kg

4,80 kg

3000 VA

Ø 185

H 75

97 %

100 mA

1,03

2,65 kg

8,30 kg

5000 VA

Ø 210

H 100

97 %

300 mA

1,03

4,90 kg

14,0 kg

7500 VA

Ø 260

H 105

97 %

400 mA

1,03

7,20 kg

23,0 kg

10000 VA

Ø 325

H 110

98 %

450 mA

1,02

13,6 kg

39,0 kg

45000 VA / 400 Hz

Ø 410

H 370

-

-

-

-

200 kg

Technical changes and optimisation reserved. All details are guide values, variations are possible.

08/2013

Beispiel Breitbandtrafo

Sekundär-
leistung

Abmessungen
in mm

Höhenangabe
ohne Befestigung

Frequenz

Leerlaufstrom

Kupfergewicht

Gesamtgewicht

BV

80 VA

Ø 100

50

30-25.000 Hz

7 mA

0,95 kg

1,6 kg

1567102

3000 VA

Ø 250

105

200-500 Hz

490 mA

3,5 kg

20,3 kg

14009015

3600 VA

Ø 215

100

1 kHz

110 mA

4,12 kg

12,0 kg

3469005


© 2023 Tauscher Transformatoren GmbH                                                                                                                                   Impressum / Privacy Policy