Secondary power
|
Dimensions
|
Height without mounting
|
Efficiency
|
No-load current
|
Voltage factor
|
Copper weight
|
Total weight
|
15 VA
|
Ø 59
|
H 29
|
80 %
|
6 mA
|
1,17
|
0,10 kg
|
0,33 kg
|
20 VA
|
Ø 60
|
H 30
|
82 %
|
6 mA
|
1,17
|
0,17 kg
|
0,44 kg
|
30 VA
|
Ø 74
|
H 30
|
84 %
|
6 mA
|
1,16
|
0,18 kg
|
0,53 kg
|
40 VA
|
Ø 76
|
H 35
|
88 %
|
8 mA
|
1,14
|
0,25 kg
|
0,69 kg
|
50 VA
|
Ø 79
|
H 37
|
88 %
|
8 mA
|
1,14
|
0,26 kg
|
0,73 kg
|
80 VA
|
Ø 90
|
H 38
|
90 %
|
10 mA
|
1,11
|
0,40 kg
|
1,01 kg
|
100 VA
|
Ø 92
|
H 43
|
93 %
|
10 mA
|
1,11
|
0,45 kg
|
1,25 kg
|
120 VA
|
Ø 95
|
H 46
|
92 %
|
11 mA
|
1,10
|
0,48 kg
|
1,35 kg
|
150 VA
|
Ø 96
|
H 50
|
93 %
|
12 mA
|
1,09
|
0,64 kg
|
1,64 kg
|
200 VA
|
Ø 115
|
H 50
|
94 %
|
15 mA
|
1,08
|
0,71 kg
|
2,04 kg
|
225 VA
|
Ø 116
|
H 52
|
94 %
|
16 mA
|
1,07
|
0,86 kg
|
2,23 kg
|
250 VA
|
Ø 117
|
H 60
|
94 %
|
17 mA
|
1,07
|
0,92 kg
|
2,57 kg
|
300 VA
|
Ø 125
|
H 62
|
94 %
|
18 mA
|
1,06
|
1,24 kg
|
2,97 kg
|
400 VA
|
Ø 132
|
H 61
|
95 %
|
20 mA
|
1,06
|
1,66 kg
|
3,73 kg
|
500 VA
|
Ø 142
|
H 71
|
96 %
|
25 mA
|
1,05
|
1,90 kg
|
4,23 kg
|
600 VA
|
Ø 140
|
H 80
|
96 %
|
28 mA
|
1,05
|
1,95 kg
|
4,84 kg
|
700 VA
|
Ø 145
|
H 86
|
96 %
|
30 mA
|
1,05
|
2,24 kg
|
4,95 kg
|
800 VA
|
Ø 173
|
H 70
|
97 %
|
32 mA
|
1,04
|
2,50 kg
|
6,20 kg
|
900 VA
|
Ø 173
|
H 78
|
97 %
|
40 mA
|
1,04
|
3,00 kg
|
7,00 kg
|
1000 VA
|
Ø 175
|
H 78
|
97 %
|
50 mA
|
1,04
|
3,50 kg
|
7,40 kg
|
1000 VA
|
Ø 200
|
H 70
|
97 %
|
50 mA
|
1,04
|
3,50 kg
|
9,60 kg
|
1200 VA
|
Ø 200
|
H 75
|
97 %
|
60 mA
|
1,03
|
4,40 kg
|
9,60 kg
|
1500 VA
|
Ø 210
|
H 84
|
97 %
|
70 mA
|
1,03
|
4,60 kg
|
10,5 kg
|
2000 VA
|
Ø 220
|
H 100
|
97 %
|
80 mA
|
1,03
|
7,50 kg
|
15,5 kg
|
2000 VA
|
Ø 200
|
H 110
|
97 %
|
80 mA
|
1,03
|
7,50 kg
|
16,9 kg
|
3000 VA
|
Ø 248
|
H 113
|
97 %
|
100 mA
|
1,03
|
10,0 kg
|
20,3 kg
|
4700 VA
|
Ø 272
|
H 100
|
97 %
|
300 mA
|
1,03
|
14,0 kg
|
28,0 kg
|
6800 VA
|
Ø 320
|
H 100
|
97 %
|
400 mA
|
1,03
|
20,0 kg
|
40,5 kg
|
10000 VA
|
Ø 350
|
H 150
|
98 %
|
450 mA
|
1,02
|
24,0 kg
|
72,0 kg
|
Technical changes and optimisation reserved. All details are guide values, variations are possible. Other dimensions and technical changes on request.
|
02/2012
|
|
|