banner oben

Transformer for switch mode power suppliesThis page in German
EFD 10 - EFD 30  1,3VA up to 110VA

HF-transformer, switch mode power supply transformer, ferrite transformer
Catalogue HF-components as PDF

 

open
potted

 

Description

Performance

HF-transformer conform to IEC/EN61558-2-17 for SMPS

 

HF-transformer, HF-inverter, ferrite trasnformer, SMPS transformer

Application

Suitable as HF-transformer for power integrations (TOPSWITCH,TINYSWITCH), Advanced Techology and ST(VIPer).  This size can also be built as a choke.

Voltages

according to customer specification, more than one input and output voltages are possible

Frequency

20 kHz up to 300 kHz, special types up to 500 kHz

Core material

N87 or PL7 for high power, with other materials it’s less power

Temperature class

F (155°C) if varnished and B(130°C) if potted

Temperature

Ambient 40°C, higher ambient temperatures decrease the power

Protective class

Fire class UL94V0, IP00 conform to DIN 40 050

Winding

with lacquered copper wire, HF litz, foil or triple insulated Furukawa wire, interlaced constrcution for best magnetic coupling

Construction

varnished under vacuum (open version) with class H varnish or potted under vacuum in a housing

Terminals

Print, SMD version or free wires

Safety

Margins to redeem air- and creepage distances. A screening is possible, but the secondary power will decrease.

 

 

 

Table

 

Power - N87/PL7

 

Type size

Frequency

Flyback

Forward

Push-pull

 

EFD

10

50

kHz

1,3

VA

1,5

VA

2,2

VA

PDF

 

 

100

kHz

1,9

VA

2,2

VA

3,1

VA

 

 

 

150

kHz

2,4

VA

2,8

VA

4,0

VA

 

EFD

15

50

kHz

4,2

VA

5,0

VA

7,0

VA

PDF

 

 

100

kHz

6,0

VA

7,0

VA

10,0

VA

 

 

 

150

kHz

8,0

VA

9,0

VA

13,0

VA

 

EFD

20

50

kHz

12,0

VA

14,0

VA

20,0

VA

PDF

 

 

100

kHz

17,0

VA

20,0

VA

28,0

VA

 

 

 

150

kHz

21,0

VA

25,0

VA

35,0

VA

PDF

EFD

25

50

kHz

27,0

VA

32,0

VA

45,0

VA

 

 

 

100

kHz

40,0

VA

45,0

VA

65,0

VA

PDF

 

 

150

kHz

45,0

VA

53,0

VA

75,0

VA

 

EFD

30

50

kHz

36,0

VA

42,0

VA

60,0

VA

PDF

 

 

100

kHz

50,0

VA

60,0

VA

85,0

VA

 

 

 

150

kHz

66,0

VA

77,0

VA

110,0

VA

 

Technical changes and optimization reserved