Catalogue HF as PDF Catalogue RM 4 - RM 14 as PDF HF-transformer, HF-transducer, ferrite transformer, switch mode power supply, RM 4 -RM 14, 1,7 VA up to 250 VA
|
|
|
|
open potted power application
|
|
Description
|
|
Design
Application
Voltages Frequency Core material Temperatureclass Temperature Protective class Winding
Construction Terminals Safety
|
HF-transformer conform to IEC/EN 61558-2-17 for SMPS HF-transformer, HF-transducer, ferrite transformer, SMPS transformer Suitable as HF-transformer for power integrations (TOPSWITCH, TINYSWITCH), Advanced Technology and ST(VIPer). HF choke can also be built according to customer specification, more than one input and output voltages are possible 20 kHz up to 300 kHz, special types up to 500 kHz N87 or PL7 for high power, with other materials it’s less power F (155 °C) for varnished and B (130 °C) for potted components Ambient 40 °C, higher ambient temperature decreases the power Fire class UL94V0, IP00 conform to DIN 40 050 with lacquered copper wire, HF-litz, foil or triple insulated Furukawa wire, interlaced construction, for optimal magnetic coupling varnished under vacuum(open Version) with class H varnish or potted under vacuum in a housing Print, SMD version or free wires Margins to redeem air and creepage distances. A screening is possible, but the secondary power will decrease.
|
|
Table
|
|
Type size
|
Frequency
|
Power - N87/PL7
|
Datasheet
|
Flyback
|
Forward
|
Push-pull
|
RM 4
|
25 kHz
|
1,7 VA
|
2,0 VA
|
2,8 VA
|
PDF
|
50 kHz
|
2,4 VA
|
2,8 VA
|
4,0 VA
|
100 kHz
|
3,0 VA
|
3,5 VA
|
5,0 VA
|
RM 5
|
25 kHz
|
3,0 VA
|
3,5 VA
|
5,0 VA
|
PDF
|
50 kHz
|
4,5 VA
|
5,3 VA
|
7,5 VA
|
100 kHz
|
5,4 VA
|
6,3 VA
|
9,0 VA
|
RM 6
|
25 kHz
|
6,6 VA
|
7,7 VA
|
11,0 VA
|
PDF
|
50 kHz
|
9,6 VA
|
11,2 VA
|
16,0 VA
|
100 kHz
|
12,0 VA
|
14,0 VA
|
20,0 VA
|
RM 7
|
25 kHz
|
8,4 VA
|
9,8 VA
|
14,0 VA
|
PDF
|
50 kHz
|
11,4 VA
|
13,3 VA
|
19,0 VA
|
100 kHz
|
13,2 VA
|
15,4 VA
|
22,0 VA
|
RM 9
|
25 kHz
|
13,2 VA
|
15,4 VA
|
22,0 VA
|
PDF
|
50 kHz
|
19,8 VA
|
23,1 VA
|
33,0 VA
|
100 kHz
|
24,0 VA
|
28,0 VA
|
40,0 VA
|
RM 10
|
25 kHz
|
25,2 VA
|
29,4 VA
|
42,0 VA
|
PDF
|
50 kHz
|
36,0 VA
|
42,0 VA
|
60,0 VA
|
100 kHz
|
45,0 VA
|
52,5 VA
|
75,0 VA
|
RM 12
|
25 kHz
|
51,0 VA
|
59,5 VA
|
85,0 VA
|
PDF
|
50 kHz
|
72,0 VA
|
84,0 VA
|
120,0 VA
|
100 kHz
|
90,0 VA
|
105,0 VA
|
150,0 VA
|
RM 14
|
25 kHz
|
84,0 VA
|
98,0 VA
|
140,0 VA
|
PDF
|
50 kHz
|
120,0 VA
|
140,0 VA
|
200,0 VA
|
100 kHz
|
150,0 VA
|
175,0 VA
|
250,0 VA
|
Technical changes and optimisation reserved. All details are guide values, variations are possible.
|