We offer climatic tests
Test pieces: max. dimensions
- width 580mm
- length 765mm
- height 750mm
- weight 300 kg
Temperature tests: Temperature -72°C up to +180°C Temperature gradient 3K/min
Climatic tests +10°C up to +95°C Humdi area 10 up to 95%
Mulitstress-Tests are possible by using cable glands. High voltage test equipment up to 70 kV AC and 200 kV DC is available.
Record and documentation of the measured values by several interfaces.
|