Technical data toroidal transformers
|
|
Construction
|
|
TRZT = open with covertape
|
|
TRHT = rest hole potting
|
|
TRWT = mounted on a metal angle
|
|
TRVTP = potted in a round housing - print version
|
|
TRVTF = potted in a round housing - free wire
|
|
TRVTE = potted in a rectangular housing - print version
|
|
TRVTU = potted in a round housing - print version
|
|
Temperature class
|
|
T40/B
|
|
on request insulation class F (155°C)
|
|
Protective class
|
|
IP00 (for mounting in an appliance)
|
|
Phases
|
|
1 or 3
|
|
Frequency
|
|
48 Hz up to 400 Hz, at other frequencies than 50 Hz, the transformer will have another power at the same type size
|
|
VDE/SEV safety standards
|
|
open: EN 61558
|
|
potted: EN 61558
|
|
UL/CSA safety standards
|
|
on request UL/CSA materials or UL-approval
|
|
Test voltage
|
|
EN 61558-1-2/4: 5000 V pri -sec
|
|
Short circuit strength
|
|
partly short circuit proof with
|
|
- PTC
|
|
- temperature fuse
|
|
- temperature switch
|
|
- mini fuse
|
|
in other cases not short circuit proof
|
|
Core insulation and housing
|
|
Material:
|
|
Polyamid 6 class B = 130°C
|
|
with UL-approval UL 94 V2
|
|
Insulating tape
|
|
Polyester (Mylar) class B = 130°C
|
|
with UL-approval UL 94 V0
|
|
Copper wire
|
|
Polyimid mod. class H = 180°C
|
|
with UL-approval
|
|
Screen winding
|
|
Screen with copper tape, this reduces the max. power at the same type size
|
|
Transformer core lamination
|
|
conform to DIN 41302
|
|
M0H, 0,3 mm thick
|
|
(1,0 W/kg losses at1,7 T) orr
|
|
M111-35N, 0,35 mm thick
|
|
(1,1 W/kg losses at 1,5 T)
|
|
Terminals
|
|
with pins (TRVTP / TRVTU)
|
|
with solder tags
|
|
with free wires
|
|
with stranded, flexible wires
|
|
with terminal connectors (TRWT)
|
|
with plug pins 2,8 - 4,8 - 6,3 mm
|
|
with cable eyes
|
|
Mounting
|
|
with a central screw, two washers and a metal disk or with a screw in the potted centre
|
|
Voltage
|
|
depends on the size
|
|
max: depends on the size
|
|
vacuum casting: 5000 V
|
|
Taps
|
|
possible
|
|
Current
|
|
max: 2000 A
|