Technical data print transformers
|
|
Type size
|
|
T.O = open, vacuum varnished
|
|
T.V = potted in a housing
|
|
Temperature class
|
|
T40/B
|
|
on request temperature class F (155°C)
|
|
for type T.O possible
|
|
Protective class
|
|
IP00
|
|
Phasen
|
|
1
|
|
Frequency
|
|
48 Hz up to 400 Hz
|
|
for other frequencies than 50 Hz, we will get another power at the same size
|
|
Standards VDE/SEV
|
|
open: EN 61558
|
|
Potted: EN 61558
|
|
standards UL/CSA
|
|
on request UL/CSA materials or UL-approval
|
|
Test voltage
|
|
EN 61558-1: 2500 V pri -sec
|
|
EN 61558-2-1/4: 4000 V pri -sec
|
|
Short-circuit strength
|
|
Short-circuit proof up to 2,4 VA
|
|
Partly short-circuit proof with
|
|
- PTC
|
|
- temperature fuse
|
|
- temperature switch
|
|
- micro fuse
|
|
in other cases: not short-circuit proof
|
|
Bobbin
|
|
DIN 41302, 1 o. 2 chamber version
|
|
Material:
|
|
Polyamid 6 gf class B = 130°C
|
|
with UL-approval UL 94 V2
|
|
Pin-grid has to be given at the order
|
|
Insulation materials
|
|
Polyester (Mylar) class B = 130°C
|
|
with UL-approval UL 94 V0
|
|
Copper wire
|
|
Polyurethane mod. class F = 155°C
|
|
with UL-approval
|
|
min: 0,04 mm
|
|
max: flatcopper with approx. 500 qmm
|
|
Screen winding
|
|
made of Cu-foil, decreases the max. power
|
|
Transformer core lamination
|
|
conform toDIN 41302
|
|
M530-50A, 0,5 mm thick
|
|
(2,3 W/kg losses at1,0 T) or
|
|
M111-35N, 0,35 mm thick
|
|
(1,1 W/kg losses at 1,5 T)
|
|
Mounting
|
|
by the printed circuit board
|
|
Voltage
|
|
min: 0,1 V
|
|
max: depends on size
|
|
for EI 78 and vacuum potted: 5000 V
|
|
Tappings
|
|
possible
|
|
Current
|
|
min: 0 A
|
|
max: depends on size
|
|
Mechanical tolerances
|
|
Tolerance of print transformers from pin row to pin row: +- 0,5 mm
|
|
Printed circuit board drills
|
|

|