Technical data print transformersThis page in German

Type size

T.O = open, vacuum varnished

T.V = potted in a housing

Temperature class

T40/B

on request temperature class F (155°C)

for type T.O possible

Protective class

IP00

Phasen 

1

Frequency

48 Hz up to 400 Hz

for other frequencies than 50 Hz, we will get another power at the same size

Standards VDE/SEV

open: EN 61558

Potted: EN 61558

standards UL/CSA

on request UL/CSA materials or UL-approval

Test voltage

EN 61558-1: 2500 V pri -sec

EN 61558-2-1/4: 4000 V pri -sec

Short-circuit strength

Short-circuit proof up to 2,4 VA

Partly short-circuit proof with

- PTC

- temperature fuse

- temperature switch

- micro fuse

in other cases: not short-circuit proof

Bobbin

DIN 41302, 1 o. 2 chamber version

Material:

Polyamid 6 gf class B = 130°C

with UL-approval UL 94 V2

Pin-grid has to be given at the order

Insulation materials

Polyester (Mylar) class B = 130°C

with UL-approval UL 94 V0

Copper wire

Polyurethane mod. class F = 155°C

with UL-approval

min: 0,04 mm

max: flatcopper with approx. 500 qmm

Screen winding

made of Cu-foil, decreases the max. power

Transformer core lamination

conform toDIN 41302

M530-50A, 0,5 mm thick

(2,3 W/kg losses at1,0 T) or

M111-35N, 0,35 mm thick 

(1,1 W/kg losses at 1,5 T)

Mounting

by the printed circuit board

Voltage

min: 0,1 V

max: depends on size

for EI 78 and vacuum potted: 5000 V

Tappings

possible

Current

min: 0 A

max: depends on size

Mechanical tolerances

Tolerance of print transformers from pin row to pin row: +- 0,5 mm

Printed circuit board drills