Technical data chokesThis page in German

Type size

D.O = open, vacuum varnished

Temperature class

T40/B

on request class F (155°C)

Protective class

IP00

Phases

1 or 3

Frequency

48 Hz up to 400 Hz

at other frequencies than 50 Hz, we will get less power at the same size

Standards UL/CSA

aon request UL/CSA materials or UL-approval

Temperature guarding

- temperature switch

- thermistors

Bobbin

DIN 41302, 1 chamber version

Material

Polyamid 6 gf Klasse B = 130°C

mit UL-Zulassung UL 94 V2

Isolierstoffe

Polyester (Mylar) class B = 130°C

with UL-approval UL 94 V0

Copper wire

Polyurethane mod. class F = 155°C

with UL-approval

min: 0,04 mm

Transformer core lamination

conform to DIN 41302

M530-50A, 0,5 mm thick

(2,3 W/kg losses at 1,0 T) or

M111-35N, 0,35 mm thick 

(1,1 W/kg losses at 1,5 T)

Tappings

possible

Current

max: depends on size