transformer for switch mode power supplies RM4-RM14 1,7VA - 250VA
|
|
HF-transformer, switched mode power supply transformer, ferrite transformer catalogue “HF-components” as PDF-File
|
|
|
|
open |
potted |
power application |
|
description
|
|
performance
|
switched mode power supply transformer according to
|
|
|
IEC EN61558-2-17 for SMPS, HF-transformer, ferrite transformer
|
|
application
|
for Power Integrations (TOPSWITCH, TINYSWITCH) Advanced Techology and ST(VIPer).
|
|
|
types can also be constructed as an HF choke.
|
|
voltages
|
to customer demand, also more input and output voltages are possible
|
|
frequency
|
20 kHz to 300 kHz, extra types to 500 kHz
|
|
core material
|
N87 oder PL7 for high power, with other material less power
|
|
insulation class
|
F (155°C) for lacquered and B(130°C) for potted components
|
|
temperature
|
ambient 40°C, higher temperatures
|
|
|
decrease the secondary power
|
|
protective class
|
fire class UL94V0, IP00 according to DIN 40 050
|
|
winding
|
with lacquered copper wire, HF-litz wire, foil or triple insulated Furukawa wire, interlaced construction for best magnetic coupling
|
|
construction
|
vacuum varnished (open types) with class H impregnation varnish or vacuum potted in a case
|
|
terminals
|
Print, SMD or with free wires construction
|
|
safety
|
margins for air- and creepage-distance
|
|
|
screening possible, secondary power will decrease
|
|
|
|
|
|
|
power - N87/PL7
|
|
|
type size
|
frequency
|
flyback
|
forward
|
push-pull
|
|
|
RM 4
|
25
|
kHz
|
1,7
|
VA
|
2,0
|
VA
|
2,8
|
VA
|
PDF
|
|
50
|
kHz
|
2,4
|
VA
|
2,8
|
VA
|
4,0
|
VA
|
|
|
100
|
kHz
|
3,0
|
VA
|
3,5
|
VA
|
5,0
|
VA
|
|
|
RM 5
|
25
|
kHz
|
3,0
|
VA
|
3,5
|
VA
|
5,0
|
VA
|
PDF
|
|
50
|
kHz
|
4,5
|
VA
|
5,3
|
VA
|
7,5
|
VA
|
|
|
100
|
kHz
|
5,4
|
VA
|
6,3
|
VA
|
9,0
|
VA
|
|
|
RM 6
|
25
|
kHz
|
6,6
|
VA
|
7,7
|
VA
|
11,0
|
VA
|
PDF
|
|
50
|
kHz
|
9,6
|
VA
|
11,2
|
VA
|
16,0
|
VA
|
|
|
100
|
kHz
|
12,0
|
VA
|
14,0
|
VA
|
20,0
|
VA
|
|
|
RM 7
|
25
|
kHz
|
8,4
|
VA
|
9,8
|
VA
|
14,0
|
VA
|
PDF
|
|
50
|
kHz
|
11,4
|
VA
|
13,3
|
VA
|
19,0
|
VA
|
|
|
100
|
kHz
|
13,2
|
VA
|
15,4
|
VA
|
22,0
|
VA
|
|
|
RM 8
|
25
|
kHz
|
13,2
|
VA
|
15,4
|
VA
|
22,0
|
VA
|
PDF
|
|
50
|
kHz
|
19,8
|
VA
|
23,1
|
VA
|
33,0
|
VA
|
|
|
100
|
kHz
|
24,0
|
VA
|
28,0
|
VA
|
40,0
|
VA
|
|
|
RM 10
|
25
|
kHz
|
25,2
|
VA
|
29,4
|
VA
|
42,0
|
VA
|
PDF
|
|
50
|
kHz
|
36,0
|
VA
|
42,0
|
VA
|
60,0
|
VA
|
|
|
100
|
kHz
|
45,0
|
VA
|
52,5
|
VA
|
75,0
|
VA
|
|
|
RM 12
|
25
|
kHz
|
51,0
|
VA
|
59,5
|
VA
|
85,0
|
VA
|
PDF
|
|
50
|
kHz
|
72,0
|
VA
|
84,0
|
VA
|
120,0
|
VA
|
|
|
100
|
kHz
|
90,0
|
VA
|
105,0
|
VA
|
150,0
|
VA
|
|
|
RM 14
|
25
|
kHz
|
84,0
|
VA
|
98,0
|
VA
|
140,0
|
VA
|
PDF
|
|
50
|
kHz
|
120,0
|
VA
|
140,0
|
VA
|
200,0
|
VA
|
|
|
100
|
kHz
|
150,0
|
VA
|
175,0
|
VA
|
250,0
|
VA
|
|
|
technical changes and optimization reserved
|
|
|
|