toroidal isolating transformer in a housing 500VA until 10000 VA
|
|
1-AC toroidal isolating transformers to DIN EN 61558-2-4 and 2-6 with 5000 V / 50 Hz test voltage pri - sec power 500 VA to 10 kVA
|
|
datasheet as PDF-File
|
|
|
|

|
|

|
|

|
|
applications
|
|
toroidal isolating transformers are used for supplying loads that must have a safe insulation and an interference suppresion from the mains.
|
|
description
|
|
toroidal isolating transformers built in a housing IP 23 toroidal transformer for safety separation of voltages the windings have a low capacity construction
windings with screening low leakage current and high insulation resistance good attenuation properties against high frequency and voltage peaks low magnetic s trayfield
enclosure of insulation material with a handgrip
|
|
special types
|
|
other primary- or secondary-voltages other inslating voltages three phase type
|
|
technical data
|
|
1 AC-toroidal isolating transformer voltage range: primary 230V (TT-net) and secondary 230 V screen: static screen between pri and sec frequency: 47-63 Hz
test voltage primary - secondary: 5000 V / 50 Hz steel housing covered, colour RAL 7032, grey temperature class according to IEC 85: B max. ambient temperature: 40°C fire class: UL94 V0
open toroidal transformer class IP23 terminals: pri 2m supply cable with plug, sec socket outlet without PE alternative: PG cable coupling in block terminals inside
|
|
table
|
|
sec.- power
|
dimensions in [mm]
|
efficiency
|
noload- current
|
voltage- factor U0/UL
|
copper- weight
|
total- weight
|
|
L
|
B
|
H
|
|
500 VA
|
183
|
183
|
152
|
96%
|
25 mA
|
1,05
|
1,90 kg
|
4,65 kg
|
|
600 VA
|
183
|
183
|
152
|
96%
|
28 mA
|
1,05
|
1,95 kg
|
5,35 kg
|
|
700 VA
|
183
|
183
|
152
|
96%
|
30 mA
|
1,05
|
2,24 kg
|
5,50 kg
|
|
800 VA
|
183
|
183
|
152
|
97%
|
32 mA
|
1,04
|
2,50 kg
|
6,85 kg
|
|
900 VA
|
183
|
183
|
152
|
97%
|
40 mA
|
1,04
|
3,00 kg
|
7,70 kg
|
|
1000 VA
|
183
|
183
|
152
|
97%
|
50 mA
|
1,04
|
3,50 kg
|
8,15 kg
|
|
1000 VA
|
254
|
222
|
192
|
97%
|
50 mA
|
1,04
|
3,50 kg
|
10,6 kg
|
|
1200 VA
|
254
|
222
|
192
|
97%
|
60 mA
|
1,03
|
4,40 kg
|
10,6 kg
|
|
1400 VA
|
254
|
222
|
192
|
97%
|
70 mA
|
1,03
|
4,60 kg
|
11,6 kg
|
|
2000 VA
|
298
|
220
|
220
|
97%
|
80 mA
|
1,03
|
7,50 kg
|
17,1 kg
|
|
2000 VA
|
298
|
220
|
220
|
97%
|
80 mA
|
1,03
|
7,50 kg
|
18,6 kg
|
|
3000 VA
|
398
|
280
|
280
|
97%
|
100 mA
|
1,03
|
10,0 kg
|
22,3 kg
|
|
4700 VA
|
398
|
280
|
280
|
97%
|
300 mA
|
1,03
|
14,0 kg
|
30,8 kg
|
|
6800 VA
|
478
|
350
|
300
|
97%
|
400 mA
|
1,03
|
20,0 kg
|
44,6 kg
|
|
10000 VA
|
556
|
380
|
300
|
98%
|
450 mA
|
1,02
|
24,0 kg
|
79,2 kg
|
|
technical changes and optimization reserved
|
|
|
|