cast resin high-voltage transformer until 30 kV
|
|
high voltage transformer until 30 kV, power 1VA to 3000 VA datasheet as PDF-File
|
|
|
|
BV 3004001 |
|
applications
|
|
high voltage transformers are used for test transformers e.g. for area insulating materials
|
|
technical data
|
|
1AC-high voltage transformer voltage range primary: 230 V voltage range secondary: 30 kV rated power: 30 kVA insulating: 45 kVDC frequency: 50 Hz
construction: open - winding potted
|
|
description
|
|
Test transformers are used to generate high, distortion free voltages at low power. Because of that, high voltage testing transformers differ from power transformers in construction
and dimensioning. Testing transformers are one-phase constructions and they have a high winding ratio. As a result of high voltages that have to be insulated, comparatively huge isolation spaces are needed and
as a consequence high magnetic stray fields resp. high short cut voltages uk occur. The iron core is constructed in a way that makes the flux density roughly remain in the linear area of the characteristic magnetization diagram. Cheap sophisticated and environment-friendly substitution for oil-immersed transformers.
|
|
table
|
|
type
|
type size
|
sec.- power
|
sec.- voltage
|
dimensions in [mm]
|
copper- weight
|
total- weight
|
BV
|
|
l
|
b
|
h
|
|
TUV..H
|
UI 168/58
|
400 VA
|
20 kV
|
225
|
120
|
275
|
8,9 kg
|
27,5 kg
|
|
|
TUV..H
|
UI 168/58
|
600 VA
|
24 kV
|
225
|
120
|
275
|
8,9 kg
|
27,5 kg
|
|
|
TUV..H
|
UI 168/58
|
2000 VA
|
7 kV
|
225
|
120
|
275
|
8,9 kg
|
27,5 kg
|
|
|
TUV..H
|
UI 210/73
|
2000 VA
|
15 kV
|
280
|
198
|
416
|
23 kg
|
55 kg
|
3004001
|
|
TUV..H
|
UI 210/73
|
2250 VA
|
15 kV
|
280
|
145
|
330
|
18,1 kg
|
55 kg
|
3372001
|
|
TUV..H
|
UI 300/100
|
3000 VA
|
30 kV
|
400
|
290
|
550
|
25,2 kg
|
120 kg
|
|
|
TUV..H
|
UI 300/100
|
10000 VA
|
15 kV
|
400
|
290
|
550
|
25,2 kg
|
120 kg
|
1632001
|
|
technical changes and optimization reserved
|
08/2008
|
|
|
|