performance
|
switched mode power supply transformer according to
|
|
|
IEC EN61558-2-17 for SMPS, HF-transformer, ferrite transformer
|
|
application
|
for Power Integrations (TOPSWITCH, TINYSWITCH) Advanced Techology and ST(VIPer).
|
|
|
types can also be constructed as an HF choke.
|
|
voltages
|
to customer demand, also more input and output voltages are possible
|
|
frequency
|
20 kHz to 300 kHz, extra types to 500 kHz
|
|
core material
|
N87 oder PL7 for high power, with other material less power
|
|
insulation class
|
F (155°C) for lacquered and B(130°C) for potted components
|
|
temperature
|
ambient 40°C, higher temperatures
|
|
|
decrease the secondary power
|
|
protective class
|
fire class UL94V0, IP00 according to DIN 40 050
|
|
winding
|
with lacquered copper wire, HF-litz wire, foil or triple insulated Furukawa wire, interlaced construction for best magnetic coupling
|
|
construction
|
vacuum varnished (open types) with class H impregnation varnish or vacuum potted in a case
|
|
terminals
|
Print, SMD or with free wires construction
|
|
safety
|
margins for air- and creepage-distance
|
|
|
screening possible, secondary power will decrease
|