Datasheet as PDF
One-phase line reactor

Single-phase line reactor

Line reactor upright

 

Field of application

Line reactor, commutation reactor, smoothing reactor, PFC reactor

 

Description

The size is determined by the energy E = 0,5 x L x I2. All given values are calculated for low warming and low humming. With forced cooling, smaller dimensions are possible. If there is only a bit of over temperature allowed, the dimensions will increase.

Reactors for one-phase loads and electronic devices with the following advantages:

Use as a smoothing reactor or commutation reactor in DC circuits:

  • low ripple factor
  • attenuation of current harmonics
  • bridging of line failures
  • limitation of peak currents

Use as a line reactor:

  • attenuation of current harmonics
  • limitation of start-up current
  • guarantee of short-circuit voltage of 4% to line

Use as a PFC reactor:

  • reduction of harmonics

Use as an armature circuit reactor:

  • reduction of harmonics in the motor and thus an increasement of the motor efficiency at
    one-phase applications
  • reduction of current noises in the motor
  • increasement of the total inductance of the motor circuit for DC motors with low inductance

 

Table

Type

Type size

Energy
0,5 x L x I²
[mWs]

Dimensions in mm

Mounting holes

Copper-
weight

Ttotal
weight

b

l

l1

h

h1

f1

f2

f3

f

DUO

UI 75/41,5

810

120

125

150

88

105

100

102

5,8

9

1,0 kg

3,6 kg

DUO

UI 90/31,5

900

120

150

180

78

95

120

102

5,8

9

1,55 kg

4,5 kg

DUO

UI 90/51,5

1600

120

150

180

98

115

120

102

5,8

9

2,10 kg

6,8 kg

DUO

UI 102/57

1800

144

170

200

109

127

136

126

5,8

9

2,55 kg

9,2 kg

DUO

UI 114/40

2500

144

190

225

92

110

152

126

5,8

9

2,70 kg

8,6 kg

DUO

UI 114/64

2700

144

190

225

116

134

152

126

5,8

9

3,50 kg

12,9 kg

DUO

UI 120/51

2700

166

200

235

109

130

160

146

7

13

4,5 kg

12,8 kg

DUO

UI 120/61

3500

166

200

235

119

140

160

146

7

13

4,7 kg

14,6 kg

DUO

UI 120/71

5000

166

200

235

129

150

160

146

7

13

5,20 kg

16,7 kg

DUO

UI 132/46

6200

166

220

260

106

139

176

146

7

13

5,20 kg

14,4 kg

DUO

UI 132/60

7000

166

220

260

120

144

176

146

7

13

5,50 kg

17,4 kg

DUO

UI 132/72

7500

166

220

260

132

156

176

146

7

13

5,80 kg

20,0 kg

DUO

UI 150/52

7500

200

250

295

118

144

200

174

7

13

7,30 kg

20,7 kg

DUO

UI 150/65

11000

200

250

295

131

157

200

174

7

13

8,90 kg

25,7 kg

DUO

UI 150/77

12000

200

250

295

143

169

200

174

7

13

9,10 kg

28,9 kg

DUO

UI 150/92

13000

200

250

295

158

184

200

174

7

13

9,30 kg

32,7 kg

DUO

UI 150/103

13500

200

250

295

169

195

200

174

7

13

9,80 kg

36,0 kg

DUO

UI 168/75

13000

225

280

330

147

169

224

192

7

13

11,4 kg

35,4 kg

DUO

UI 168/92

14000

225

280

330

164

186

224

192

7

13

12,6 kg

42,0 kg

DUO

UI 180/63

15000

240

300

350

145

168

240

204

9

13

14,0 kg

37,6 kg

DUO

UI 180/78

16000

240

300

350

160

182

240

204

9

13

14,7 kg

43,6 kg

DUO

UI 180/93

17000

240

300

350

175

197

240

204

9

13

16,2 kg

50,6 kg

DUO

UI 210/63

20000

280

350

410

154

176

280

234

9

13

25,6 kg

58,0 kg

DUO

UI 210/73

22000

280

350

410

164

186

280

234

9

13

27,3 kg

71,8 kg

DUO

UI 210/88

23000

280

350

410

179

201

280

234

9

13

28,5 kg

73,0 kg

DUO

UI 210/103

25000

280

350

410

194

218

280

234

9

13

35,4 kg

87,0 kg

DUO

UI 210/133

30000

280

350

410

224

247

280

234

9

13

38,2 kg

 105,0kg

DUO

UI 240/110

56000

320

400

480

223

238

320

264

12

18

44,0 kg

116,0kg

DUO

UI 240/140

80000

320

400

480

253

268

320

264

12

18

46,5 kg

140,0kg

DUO

UI 360/150

120000

492

360

-

655

-

255

310

11,0

-

110,0 kg

310,0 kg

The dimensions l and f1 are given without air gap. These will change with the thickness of the air gap.
Technical changes and optimization reserved

01/2010